Product Paramenters
Sampling interval |
1~9999min(adjustable) |
Number of sampling bottles |
1 bottle, capacity: 3L, material: PE |
Single sampling volume |
1~2500mL |
Sampling error |
士7% |
Proportional sampling error |
±8% |
Sampling vertical height |
≥6.5 meter
|
Horizontal sampling distance |
≥65 meter
|
Piping system air tightness |
≤-0.085MPa
|
Water sample refrigeration temperature |
(0~5)°C |
Mean time between failures |
≥1440h/time |
Powered Supply |
AC220V±10%, frequency 50Hz±1% |
Built-in battery |
Can run for more than 6 hours in case of power failure (no sampling and no cooling) |
Operating temperature |
5°C~40℃ |
Operating humidity |
≤90%RH (no condensation) |
Data storage capacity |
Sampling records ≥ 1000, alarm records ≥ 1000 |
Dimensions |
450mmx345mmx540mm |
Function Features
Usage |
Portable sampler, powered by mains electricity (can be powered by outdoor AC220V power supply); |
Multiple sampling modes |
It can realize timing sampling, time proportional sampling, flow proportional sampling and external control sampling; |
Multiple sampling methods |
Single sampling and mixed sampling; |
Fixative Addition |
Automatically add one type of fixative, configurable (sulfuric acid, hydrochloric acid, nitric acid, NaOH, etc.). |
Water Sample Refrigeration |
A refrigerator is available to refrigerate water samples. |
Sampling Recording |
Records sampling date and time, sampling mode, sampling volume, fixed dose, and whether the sampling was successful. Records up to 1,000 data entries, with page-by-page navigation; |
Power Outage Recording |
Records power outage and power-on times, with up to 1,000 records and page-by-page browsing; |
Alarm recording function |
Record alarm information and be able to query alarm time and status. |
Power-off Protection |
If the instrument is powered off and then back on while in operation, the sampler's previously set parameters, sampling history, and other information are retained. |
Automatic Drain Function |
After each sampling session, the system automatically drains the water in the tube to prevent sedimentation and blockage; |
Rinse Function |
Before each sampling session, the system automatically rinses the tube with the water sample to be collected, ensuring that each sample does not interfere with another; |
Video Recording Function (Optional) |
Captures video of the sampler top and inlet for remote viewing; |
Remote Communication Function (Optional) |
Equipped with a mobile app for remote control. |
GPS Positioning Function (Optional) |
The device features built-in GPS positioning, allowing for the setting of electronic fences and automatic alarms when exceeding a specified area; |
Wireless Transmission Function (Optional) |
Equipped with a 4G DTU, the device can be remotely monitored and controlled. |
Application Overview
The DR-803C5 automatic water sampler utilizes embedded control technology and offers multiple sampling modes, including timed sampling, time-proportional sampling, flow-proportional sampling, and externally controlled sampling. It also features single-shot and mixed sampling. It also includes features such as leak alarm, video recording, sample refrigeration, and power-off protection, making it an intelligent automatic water sampler.
It can be widely used for sampling pollution sources, rivers, and lakes. Its compact size, portability, ease of use, and versatile operation make it particularly suitable for on-site environmental law enforcement and mixed sampling by disease control departments.