DOZ-6850

DOZ-6850 online Dissolved Ozone Controller is a micro computerized precision instrument. Adopt the advanced non-film constant voltage sensor, no need to replace the diaphragm and pharmaceuticals. High sensitivity, rapid signal response, accurate measurement, stable performance, easy maintenance. The large LCD display, English menu operation. Multi-parameter display: The value of dissolved ozone, temperature, output current and has range transfinite alarm. With factory reset function, slope correction function. Automatic/Manual Temperature Compensation: 0℃ to 60℃ The control interface: two groups of ON/OFF relay contact, divided into high and low alarm signal photoelectric isolation output. The third group relay: automatic cleaning control function analog output.(Optional) Relay lag quantity any setting, relay load 3 A 220 vac/24 VD Communication function (optional): RS-485 communication interface , 4 to 20 mA current output corresponding to the Ozone value can be set freely. Hysteresis amount can be set freely to avoid frequent switching relay action Watchdog function: to ensure that the instrument will not crash Core devices from famous foreign brands Restore the factory settings. Power-down protection> 10 years IP65 protection enclosure.

Product Details

Product Details

Contact Now

Contact Now

Product Details

Application

Widely used for continuous monitoring and control of ozone content in aqueous solutions for drinking water treatment plants, canning plants, drinking water distribution networks, swimming pools, cooling circulating water, water treatment etc.

 

Main Technique Specification

 

DOZ-6850

online Dissolved Ozone Controller with sensor

Measuring Range

0.00 - 20.00 mg /L (ppm)

0-60℃,

Resolution

0. 01 mg/L,

0.1℃

Accuracy

 ± 1%FS or ±0.01mg/L

±0.5℃

 

Display

Large Screen Multi-parameters LCD

Temp. Compensation

Automatic/Manual temperature compensation(0-60℃)

Current output

isolation to protect , 4 ~ 20mA signal output

Control output

two sets of ON / OFF relay contacts, divided into the high

point, low alarm signal , optically isolated output.

The third group relay: automatic cleaning control function analog output.(Optional)

 

Communication output

Standard Modbus RS485 function to PC (optional)

Contact capacity

Relay lag quantity any setting, relay load 3 A 220 vac/24 VDC

Output load

load <750Ω (4-20mA)

Power

AC 220V±10%, 50/60Hz

Working environment

Ambient Temp. 0-60℃, Relative Humidity ≤90%

Dimensions

96×96×156mm(H X W X D), 0.9kgs

Hole size

92×92mm (H X W)

Installation Mode

Panel Mounted, Pipe and wall mounted

Protection grade:

 IP 65 enclosure

Doz-6850 Ozone Controller With Sensor

 

Matched Sensor

 

 

 

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

Frequently Asked Questions (FAQ) About Doz-6850

What does the Doz-6850 controller do?

Down Down

Online monitoring of dissolved ozone concentration.

How to install the Doz-6850 controller?

Down Down

Install sensor wiring at the selected location.

How to maintain Doz-6850 controller?

Down Down

Clean and calibrate regularly and check the circuit.

Doz - 6850 Why is the reading inaccurate?

Down Down

Sensor failure or miscalibration.
DOZ-6850-9.webp                  
       
                

Related Products

right
right
Soil Tester

Soil Tester

EC/TDS-TRA-600

EC/TDS-TRA-600

RO-8100

RO-8100

PH-TRA-600

PH-TRA-600

PH/ORP-6850

PH/ORP-6850

ORP-TRA-600

ORP-TRA-600

EC/TDS-500/600

EC/TDS-500/600

EC/TDS/RM-6850

EC/TDS/RM-6850

Related News

right
right
Understanding Turbidity Meter Types: Which One Is Right for Your Application?

Apr.21,2025

Understanding Turbidity Meter Types: Which One Is Right for Your Application?

Monitoring turbidity—an indicator of water clarity—is vital for applications ranging from drinking water treatment to environmental monitoring.

Understanding Total Dissolved Solids

Apr.21,2025

Understanding Total Dissolved Solids

Water may look clear, but that doesn’t mean it's pure. Hidden within every glass can be a range of minerals, salts, metals, and organic substances collectively known as total dissolved solids.

Transmitter 4 20mA Technology

Apr.21,2025

Transmitter 4 20mA Technology

In the world of industrial automation and process control, accurate signal transmission is everything.

Smart RO System Controller

Apr.21,2025

Smart RO System Controller

In today’s world, clean water isn’t just a luxury—it’s a necessity. Whether in residential settings or industrial applications, ensuring a consistent supply of high-quality water has become vital.

Residual Chlorine Meter is Essential

Apr.21,2025

Residual Chlorine Meter is Essential

Chlorination is one of the most widely used methods for disinfecting water, whether it’s for municipal supply, swimming pools, or industrial processes.

Essential Water Sampler Types

Apr.21,2025

Essential Water Sampler Types

When it comes to environmental analysis, wastewater treatment, or drinking water inspection, water sampler types play a crucial role in collecting representative water samples for laboratory analysis.

Dissolved Oxygen Meter

Apr.21,2025

Dissolved Oxygen Meter

Water may look clean, but what’s happening on the molecular level often tells a different story.

Different Types of Sensors in Industrial Automation

Apr.21,2025

Different Types of Sensors in Industrial Automation

In the rapidly evolving age of smart manufacturing and Industry 4.0, the different types of sensors deployed across production facilities are nothing short of transformative.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


hi_INHindi

Fatal error: Uncaught TypeError: Cannot access offset of type string on string in /home/www/wwwroot/HTML/www.exportstart.com/wp-content/plugins/translatepress-multilingual/includes/class-error-manager.php:44 Stack trace: #0 /home/www/wwwroot/HTML/www.exportstart.com/wp-content/plugins/translatepress-multilingual/includes/queries/class-query.php(1441): TRP_Error_Manager->record_error() #1 /home/www/wwwroot/HTML/www.exportstart.com/wp-content/plugins/translatepress-multilingual/includes/queries/class-query.php(128): TRP_Query->maybe_record_automatic_translation_error() #2 /home/www/wwwroot/HTML/www.exportstart.com/wp-content/plugins/translatepress-multilingual/includes/class-translation-render.php(1542): TRP_Query->get_existing_translations() #3 /home/www/wwwroot/HTML/www.exportstart.com/wp-content/plugins/translatepress-multilingual/includes/class-translation-render.php(909): TRP_Translation_Render->process_strings() #4 [internal function]: TRP_Translation_Render->translate_page() #5 /home/www/wwwroot/HTML/www.exportstart.com/wp-includes/functions.php(5471): ob_end_flush() #6 /home/www/wwwroot/HTML/www.exportstart.com/wp-includes/class-wp-hook.php(324): wp_ob_end_flush_all() #7 /home/www/wwwroot/HTML/www.exportstart.com/wp-includes/class-wp-hook.php(348): WP_Hook->apply_filters() #8 /home/www/wwwroot/HTML/www.exportstart.com/wp-includes/plugin.php(517): WP_Hook->do_action() #9 /home/www/wwwroot/HTML/www.exportstart.com/wp-includes/load.php(1304): do_action() #10 [internal function]: shutdown_action_hook() #11 {main} thrown in /home/www/wwwroot/HTML/www.exportstart.com/wp-content/plugins/translatepress-multilingual/includes/class-error-manager.php on line 44