DO-6800
DO-6800 online Dissolved Oxygen Temperature Transmitting Controller is a micro computerized precision instrument. The large LCD display, English menu operation. Multi-parameter display at the same time: the value of dissolved oxygen, temperature, output current, alarm points, etc. Intuitive and easy to read, and alarm for range over run Screen displays alarm status and accompanied by a switch ON / OFF signal output Automatic Temperature Compensation: Automatic 0℃ to 60℃ Communication function (optional): RS-485 communication interface (MODBUS protocol is partially compatible), 4 to 20 mA current output corresponding to the DO value can be set freely. Notepad: can store 50 measurements, the user can record measurement data. Hysteresis amount can be set freely to avoid frequent switching relay action Watchdog function: to ensure that the instrument will not crash Core devices from famous foreign brands Restore the factory settings. Power-down protection> 10 years
Product Details
Contact Now
Product Details
Application
Widely used in the detection and control of dissolved oxygen in various water treatments, boiler water deoxygenization, environmental monitoring, aquaculture and other fields.
Main Technique Specification
DO-6800 online Dissolved Oxygen Temperature Transmitting Controller with Polarography DO sensor |
|
Measuring Range |
0.0 - 20.00 mg /L (ppm) (standard version) 0 - 200.0 ug /L (ppd), (optional) 0-60℃, 0-100℃ (optional), , 0-100℃ (optional), |
Resolution |
0.1 ug/L, 0. 01 mg/L, 0.1℃ |
Accuracy |
ug/L: ±20%FS; mg/L:±2%FS, ±0.3℃
|
Display |
Large Screen Multi-parameters LCD |
Temp. Compensation |
NTC 10K, 0.0℃-60.0 ℃, 0-100℃ (optional), Automatic temperature compensation |
Current output |
isolation to protect , 4 ~ 20mA signal output |
Control output |
two sets of ON / OFF relay contacts, divided into the high point, low alarm signal , optically isolated output.
|
Communication output |
Standard Modbus RS485 function to PC (optional) |
Contact capacity |
10A/220V AC (Resistive Load) |
Output load |
load <500Ω (0-10mA), load <750Ω (4-20mA) |
Power |
AC 220V±10%, 50/60Hz |
Working environment |
Ambient Temp. 0-60℃, Relative Humidity ≤90% |
Dimensions |
96×96×115mm(H X W X D), 0.9kgs |
Hole size |
91×91mm H X W) |
Installation Mode |
Panel Mounted |
Protection grade: |
IP57 |
DO Controller With Polarography DO Sensor
![]() |
![]() |
Main Technique Specification
DO-6800 Online Dissolved Oxygen Temperature Transmitting Controller with Galvanic DO sensor |
|
Measuring Range |
0.00 - 20.00 mg /L (ppm) standard version 0 - 200.0 ug /L (ppd), (optional) 0-60℃, 0-100℃ (optional), |
Resolution |
0.1 ug/L, 0. 01 mg/L, 0.1℃ |
Accuracy |
ug/L: ±2.0%FS; mg/L:±2%FS, ±0.3℃
|
Display |
Large Screen Multi-parameters LCD |
Temp. Compensation |
NTC 10K, 0.0℃-60.0 ℃, 0-100℃ (optional), Automatic temperature compensation |
Current output |
isolation to protect , 4 ~ 20mA signal output |
Control output |
two sets of ON / OFF relay contacts, divided into the high point, low alarm signal , optically isolated output.
|
Communication output |
Standard Modbus RS485 function to PC (optional) |
Contact capacity |
10A/220V AC (Resistive Load) |
Output load |
load <500Ω (0-10mA), load <750Ω (4-20mA) |
Power |
AC 220V±10%, 50/60Hz |
Working environment |
Ambient Temp. 0-60℃, Relative Humidity ≤90% |
Dimensions |
96×96×115mm(H X W X D), 0.9kgs |
Hole size |
91×91mm H X W) |
Installation Mode |
Panel Mounted |
Protection grade: |
IP57 |
DO-6800 Controller With Galvanic Sensor
|
|
![]() |
![]() |
Get in Touch
If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.
FAQS
What does the Do-6800 controller do?
How do I install the Do-6800 controller?
How to maintain Do-6800 controller?
Do - 6800 Why is the reading inaccurate?
Related Products
Related News
May.22,2025
Turbidity Test Fixtures: Advanced and Reliable Quality Assurance Tools
Turbidity, as an important indicator for measuring liquid transparency, is widely used in environmental monitoring, food and beverage production, pharmaceutical industry, and other fields.
May.22,2025
Total Dissolved Solids: Importance in Irrigation, Industrial Processes, and Applications
Total Dissolved Solids refers to the total content of various inorganic salts and organic matter dissolved in water, and is one of the important indicators for measuring water quality.
May.22,2025
Ro System Controller: Central nervous system in water purification systems
Reverse osmosis system, as an efficient water purification technology, has been widely used in industrial, commercial, and household fields.
May.22,2025
Residual Chlorine Meter: A Key Guarantee for Ensuring Water Quality Safety
Residual chlorine, as an important indicator in the process of water disinfection, directly affects the safety and hygiene of drinking water and various industrial water.
May.22,2025
PH oORP Controller: A Key Instrument for Water Quality Monitoring and Regulation
Water quality is an important indicator for measuring environmental health and industrial production.
May.22,2025
Dissolved Oxygen Meter: A Key Tool for Accurately Measuring Dissolved Oxygen Levels in Aquatic Environments
Dissolved oxygen is one of the important indicators for measuring water quality.
Apr.21,2025
Understanding Turbidity Meter Types: Which One Is Right for Your Application?
Monitoring turbidity—an indicator of water clarity—is vital for applications ranging from drinking water treatment to environmental monitoring.
Apr.21,2025
Understanding Total Dissolved Solids
Water may look clear, but that doesn’t mean it's pure. Hidden within every glass can be a range of minerals, salts, metals, and organic substances collectively known as total dissolved solids.
If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.