DO-6800 online Dissolved Oxygen Temperature Transmitting Controller is a micro computerized precision instrument. The large LCD display, English menu operation. Multi-parameter display at the same time: the value of dissolved oxygen, temperature, output current, alarm points, etc. Intuitive and easy to read, and alarm for range over run Screen displays alarm status and accompanied by a switch ON / OFF signal output Automatic Temperature Compensation: Automatic 0℃ to 60℃ Communication function (optional): RS-485 communication interface (MODBUS protocol is partially compatible), 4 to 20 mA current output corresponding to the DO value can be set freely. Notepad: can store 50 measurements, the user can record measurement data. Hysteresis amount can be set freely to avoid frequent switching relay action Watchdog function: to ensure that the instrument will not crash Core devices from famous foreign brands Restore the factory settings. Power-down protection> 10 years

Product Details

Product Details

Contact Now

Contact Now

Product Details

Application

Widely used in the detection and control of dissolved oxygen in various water treatments, boiler water deoxygenization, environmental monitoring, aquaculture and other fields.

 

DO-6800

 

Main Technique Specification

 

DO-6800

online Dissolved Oxygen Temperature Transmitting Controller with Polarography DO sensor

Measuring Range

0.0 - 20.00 mg /L (ppm) (standard version)

0 - 200.0 ug /L (ppd), (optional)

0-60℃, 0-100℃ (optional),

, 0-100℃ (optional),

Resolution

0.1 ug/L,

0. 01 mg/L,

0.1℃

Accuracy

ug/L: ±20%FS;

mg/L:±2%FS,

±0.3℃

 

Display

Large Screen Multi-parameters LCD

Temp. Compensation

NTC 10K, 0.0℃-60.0 ℃, 0-100℃ (optional),

Automatic temperature compensation

Current output

isolation to protect , 4 ~ 20mA signal output

Control output

two sets of ON / OFF relay contacts, divided into the high

point, low alarm signal , optically isolated output.

 

Communication output

Standard Modbus RS485 function to PC (optional)

Contact capacity

10A/220V AC (Resistive Load)

Output load

load <500Ω (0-10mA), load <750Ω (4-20mA)

Power

AC 220V±10%, 50/60Hz

Working environment

Ambient Temp. 0-60℃, Relative Humidity ≤90%

Dimensions

96×96×115mm(H X W X D), 0.9kgs

Hole size

91×91mm H X W)

Installation Mode

Panel Mounted

Protection grade:

IP57  

DO Controller With Polarography DO Sensor

DO-6800 DO-6800

Main Technique Specification

 

DO-6800

Online Dissolved Oxygen Temperature Transmitting Controller with Galvanic DO sensor

Measuring Range

0.00 - 20.00 mg /L (ppm) standard version

0 - 200.0 ug /L (ppd), (optional)

0-60℃, 0-100℃ (optional),

Resolution

0.1 ug/L,

0. 01 mg/L,

0.1℃

Accuracy

ug/L: ±2.0%FS;

mg/L:±2%FS,

±0.3℃

 

Display

Large Screen Multi-parameters LCD

Temp. Compensation

NTC 10K, 0.0℃-60.0 ℃, 0-100℃ (optional),

Automatic temperature compensation

Current output

isolation to protect , 4 ~ 20mA signal output

Control output

two sets of ON / OFF relay contacts, divided into the high

point, low alarm signal , optically isolated output.

 

Communication output

Standard Modbus RS485 function to PC (optional)

Contact capacity

10A/220V AC (Resistive Load)

Output load

load <500Ω (0-10mA), load <750Ω (4-20mA)

Power

AC 220V±10%, 50/60Hz

Working environment

Ambient Temp. 0-60℃, Relative Humidity ≤90%

Dimensions

96×96×115mm(H X W X D), 0.9kgs

Hole size

91×91mm H X W)

Installation Mode

Panel Mounted

Protection grade:

IP57  

 DO-6800 Controller With Galvanic Sensor

DO-6800

 

DO-6800

 

DO-6800 DO-6800

 

 

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

Frequently Asked Questions (FAQ) About Do-6800

What does the Do-6800 controller do?

Down Down

Online control of dissolved oxygen and temperature data.

How do I install the Do-6800 controller?

Down Down

Choose a location to install the sensor wiring.

How to maintain Do-6800 controller?

Down Down

Clean the calibration and check the wiring regularly.

Do - 6800 Why is the reading inaccurate?

Down Down

Sensor failure or calibration deviation.
DO-1.webp                  
       
                

Related Products

right
right
WS-9200/9250

WS-9200/9250

JIRS-803C

JIRS-803C

JIRS-803C3

JIRS-803C3

JIRS-803C4

JIRS-803C4

JIRS-803C5

JIRS-803C5

Soil Sensor

Soil Sensor

Soil Tester-LCD Screen

Soil Tester-LCD Screen

EC/TDS-TRA-600

EC/TDS-TRA-600

Related News

right
right
The Importance of a Pressure Switch for RO System Safety

Aug.21,2025

The Importance of a Pressure Switch for RO System Safety

Reverse osmosis (RO) systems are critical for ensuring clean, safe water in various settings, and their reliability hinges on robust safety mechanisms.

Low Electrical Conductivity Materials for Insulation Purposes

Aug.21,2025

Low Electrical Conductivity Materials for Insulation Purposes

In industries ranging from electronics to power transmission, the demand for reliable insulation materials hinges on their electrical conductivity properties.

Key Considerations for Selecting Turbidity Testing Devices

Aug.21,2025

Key Considerations for Selecting Turbidity Testing Devices

In water quality management, accurate measurement of turbidity—cloudiness caused by suspended particles—is essential across industries.

How to Choose the Right ORP Controller for Industrial Applications

Aug.21,2025

How to Choose the Right ORP Controller for Industrial Applications

Selecting the right orp controller for industrial applications requires a deep understanding of specific operational needs, compatibility with existing systems, and reliability in diverse environments.

Best Practices for Calibrating an Optical Dissolved Oxygen Meter

Aug.21,2025

Best Practices for Calibrating an Optical Dissolved Oxygen Meter

Calibrating an optical dissolved oxygen meter is a critical step in ensuring accurate measurements of dissolved oxygen levels in water, a parameter vital for industries like aquaculture, environmental monitoring, and water treatment.

Benefits of Using an Automated Chlorine Monitor

Aug.21,2025

Benefits of Using an Automated Chlorine Monitor

In the realm of water quality management, maintaining precise chlorine levels is paramount for safety and compliance across industries.

Water Quality: Understanding TDS

Aug.19,2025

Water Quality: Understanding TDS

When it comes to water quality, the total suspended solids meter is an essential tool.

Turbidity Control: Clarity You Can Trust

Aug.19,2025

Turbidity Control: Clarity You Can Trust

In the quest for clear and safe water, the turbidity transmitter stands out as a crucial tool.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


tlTagalog