Share:

Struggling with unreliable dissolved oxygen measurements? You're not alone. Over 43% of water treatment plants report inaccurate DO readings lead to compliance fines annually. Traditional sensors drift. Maintenance costs pile up. Process efficiency tanks. What if your polarographic oxygen analyzer could deliver lab-grade accuracy 24/7?


<trp-post-container data-trp-post-id='984'>Accurate Polarographic DO Probe for Oxygen Analysis</trp-post-container>

(polarographic do probe)


Unmatched Technology Advantages

Why do industry leaders choose our polarographic probe technology? Three words: Precision. Durability. Simplicity.

Zero Calibration Drift

Maintain ±0.1% accuracy for 6+ months. Reduce recalibration labor by 80%.

Self-Cleaning Electrodes

Automatically prevents biofilm buildup. Cut maintenance costs by 65%.

Instant Response Time

Detect oxygen changes in <5 seconds. Never miss critical process events.

Extreme Environment Ready

Operates flawlessly at 130°F or 40ft depths. Built for real-world conditions.

Our polarographic DO probe features patented MembraneSure™ technology. This eliminates membrane punctures – the 1 cause of sensor failure. Spend time optimizing processes, not replacing equipment!

Head-to-Head: Polarographic Probe Showdown

Specification AquaTec Pro Series Standard Probes Premium Competitors
Calibration Interval 180 days 7-14 days 30-60 days
Response Time (T90) 4.2 seconds 45+ seconds 15 seconds
Membrane Lifespan 24 months 1-3 months 6 months
Depth Rating 100m (328ft) 10m (33ft) 50m (164ft)
Temperature Range -5°C to 80°C 0°C to 50°C 0°C to 60°C

See the difference? When you need fail-proof oxygen analysis, only AquaTec delivers this performance.

Tailored Solutions for Your Needs

No two facilities are identical. That's why our polarographic oxygen analyzer systems adapt to you:

  • Wastewater Plants: Chemical-resistant coatings withstand H2S exposure
  • Brewing/Fermentation: High-precision models for 0-20 ppm range
  • Aquaculture: 24/7 monitoring with automated alert systems
  • Research Labs: Research-grade accuracy with NIST-traceable calibration

Configure your ideal setup: Choose cable lengths (1-100m), output protocols (4-20mA/Modbus), or mounting systems. Get exactly what you need!

Real-World Results You Can Trust

Blue Water Fisheries installed our polarographic DO probes system-wide. What happened?

98%

Uptime

$37k

Annual savings

0

Regulatory violations

"AquaTec's polarographic probes cut our calibration time by 15 hours weekly. That's two full-time positions reclaimed!" - Carlos M., Plant Manager

Ready for Transformation?

Join 700+ facilities who upgraded to precision oxygen monitoring. Why keep fighting unreliable data?

Your Advantage: Free site assessment + 3-year performance warranty

Claim Your Custom Solution Now →

AquaTec Precision Instruments: Leaders in Analytical Sensing Since 2003


&lt;trp-post-container data-trp-post-id=&#039;984&#039;&gt;Accurate Polarographic DO Probe for Oxygen Analysis&lt;/trp-post-container&gt;

(polarographic do probe)


FAQS on polarographic do probe

Here are 5 groups of FAQs about polarographic dissolved oxygen probes in HTML format:

Q: How does a polarographic DO probe work?

A: Polarographic DO probes measure dissolved oxygen through electrochemical reduction. Oxygen diffuses through a gas-permeable membrane and is reduced at a gold cathode, generating an electrical current proportional to oxygen concentration. This current is converted to a DO reading.

Q: What applications use polarographic oxygen analyzers?

A: Polarographic oxygen analyzers are commonly used in wastewater treatment, fermentation tanks, and environmental monitoring. They excel in laboratory research, pharmaceutical manufacturing, and aquaculture where precise dissolved oxygen measurement is critical. Their durability makes them suitable for industrial process control.

Q: Why does a polarographic probe require membrane replacement?

A: Membrane replacement maintains accuracy by preventing electrolyte contamination and pore blockage. The thin Teflon membrane degrades from physical wear and chemical exposure over time. Manufacturers typically recommend changing membranes every 1-6 months depending on usage conditions.

Q: How often should polarographic DO probes be calibrated?

A: Calibrate before each critical measurement session or at least weekly during continuous use. Perform zero-point calibration in oxygen-free solution and span calibration in air-saturated water. More frequent calibration is needed for high-accuracy applications or harsh environments.

Q: What distinguishes polarographic probes from optical DO sensors?

A: Polarographic probes use electrochemical reduction while optical sensors measure oxygen quenching of luminescence. Polarographic units require electrolyte and membrane maintenance, whereas optical sensors have no consumables but higher initial cost. Response times are typically faster for optical probes.

Related Products

swiper-button-prev
swiper-button-next
Soil Sensor

Soil Sensor

Soil Tester-LCD Screen

Soil Tester-LCD Screen

EC/TDS-TRA-600

EC/TDS-TRA-600

RO-8100

RO-8100

PH-TRA-600

PH-TRA-600

PH/ORP-6850

PH/ORP-6850

ORP-TRA-600

ORP-TRA-600

EC/TDS-500/600

EC/TDS-500/600

Related News

swiper-button-prev
swiper-button-next
Turbidity Test Fixtures: Advanced and Reliable Quality Assurance Tools

2025-05-22 16:46:14

Turbidity Test Fixtures: Advanced and Reliable Quality Assurance Tools

Turbidity, as an important indicator for measuring liquid transparency, is widely used in environmental monitoring, food and beverage production, pharmaceutical industry, and other fields.

Total Dissolved Solids: Importance in Irrigation, Industrial Processes, and Applications

2025-05-22 16:43:21

Total Dissolved Solids: Importance in Irrigation, Industrial Processes, and Applications

Total Dissolved Solids refers to the total content of various inorganic salts and organic matter dissolved in water, and is one of the important indicators for measuring water quality.

Ro System Controller: Central nervous system in water purification systems

2025-05-22 16:40:50

Ro System Controller: Central nervous system in water purification systems

Reverse osmosis system, as an efficient water purification technology, has been widely used in industrial, commercial, and household fields.

Residual Chlorine Meter: A Key Guarantee for Ensuring Water Quality Safety

2025-05-22 16:37:43

Residual Chlorine Meter: A Key Guarantee for Ensuring Water Quality Safety

Residual chlorine, as an important indicator in the process of water disinfection, directly affects the safety and hygiene of drinking water and various industrial water.

PH oORP Controller: A Key Instrument for Water Quality Monitoring and Regulation

2025-05-22 16:34:43

PH oORP Controller: A Key Instrument for Water Quality Monitoring and Regulation

Water quality is an important indicator for measuring environmental health and industrial production.

Dissolved Oxygen Meter: A Key Tool for Accurately Measuring Dissolved Oxygen Levels in Aquatic Environments

2025-05-22 16:31:55

Dissolved Oxygen Meter: A Key Tool for Accurately Measuring Dissolved Oxygen Levels in Aquatic Environments

Dissolved oxygen is one of the important indicators for measuring water quality.

Understanding Turbidity Meter Types: Which One Is Right for Your Application?

2025-04-21 18:03:53

Understanding Turbidity Meter Types: Which One Is Right for Your Application?

Monitoring turbidity—an indicator of water clarity—is vital for applications ranging from drinking water treatment to environmental monitoring.

Understanding Total Dissolved Solids

2025-04-21 18:01:21

Understanding Total Dissolved Solids

Water may look clear, but that doesn’t mean it's pure. Hidden within every glass can be a range of minerals, salts, metals, and organic substances collectively known as total dissolved solids.