Pressure Switch

The LF55 pressure switch is an automatic control device that responds to pressure signals and operates accordingly. It can serve as a safety protection measure in various devices such as pumps, hydraulic systems, and hydraulic machinery. Provide international standard mounting bracket for any part. SPDT switch ensures reliable contact switching. The pressure bellows of the standard model are phosphor bronze bellows, the pressure port is made of brass.

Product Details

Product Details

Contact Now

Contact Now

Product Details

Introduction

 

  • • The LF55 pressure switch is an automatic control device that responds to pressure signals and operates accordingly.
  • • It can serve as a safety protection measure in various devices such as pumps, hydraulic systems, and hydraulic machinery.
  • • Provide international standard mounting bracket for any part.
  • • SPDT switch ensures reliable contact switching.
  • • The pressure bellows of the standard model are phosphor bronze bellows, the pressure port is made of brass.

 

Working principle

By adjusting the screw of the pressure switch, the spring tension can be adjusted. The deeper the screw is screwed in, the greater the spring force that the measuring element must overcome, and the switch point value correspondingly increases. The geometric structure of the spring is designed according to the required switching range. According to the functional principle of mechanical pressure switches, the switching point is defined by the spring pre-tension, which sets the switching point when the pressure increases. When the external pressure acts on the pressure sensing element as the pressure decreases, the spring or diaphragm deforms accordingly. When the pressure reaches a certain level, the deformation of the spring or diaphragm causes a displacement in the mechanical structure, thereby closing or opening the contacts and changing the conductivity state of the circuit.

Widely used for reverse osmosis systems.

<trp-post-container data-trp-post-id='133'>Pressure Switch</trp-post-container>

 

Specification

 

<trp-post-container data-trp-post-id='133'>Pressure Switch</trp-post-container>

120V AC

250V AC

Non-induced Current

20A

10A

Induced Current

Full-load

15A

8A

Momentary

72A

 

Notice

Use two spanners to avoid damaging the controller; Install to the equipment by four M4 screws on back side of the controller directly; Use multi-purpose mounting plate, it is also easy to install. Please use screws in attachment bag when installing.

 

Model

Range(bar)

Differential (bar)

Factory Setting

(bar)

Max Airtight Test
Pressure(bar)

Min.

Max.

Min.

Max.

OFF

ON

LF5502

-0.5

2

0.2

0.7

1

0.5

16.5

LF5503

-0.5

3

0.35

1.5

2

1

16.5

LF5506

-0.5

6

0.6

4

3

2

16.5

LF5506M

-0.5

6

Reset differential≤1bar

3

Manual Reset

16.5

LF5510

1

10

1

3

6

5

16.5

LF5516

3

16

1

4

10

8

35

LF5520

5

20

2

5

16

13

35

LF5530

8

30

Fixed 3-5

20

15~17

35

LF5530M

8

30

Reset differential≤4bar

20

Manual Reset

35

LF5530D

5

30

3

10

20

15

35

LF5532

8

32

2

6

20

17

35

LF5542

8

42

4

10

30

25

46.5

 

Scale plate:two units-“bar”&“psig”;“MPa”&“Kgf/cm2”are also available;

British thread model can add“E”according to custom requirement,

Also wilding model add“C”, capillary model add“S”,such as LF5506E;

Ammonia refrigerant model add“B”,such as LF5506B.

 

Dimension

<trp-post-container data-trp-post-id='133'>Pressure Switch</trp-post-container>

<trp-post-container data-trp-post-id='133'>Pressure Switch</trp-post-container>

<trp-post-container data-trp-post-id='133'>Pressure Switch</trp-post-container>

 

 

 

Wiring Instructions

<trp-post-container data-trp-post-id='133'>Pressure Switch</trp-post-container> <trp-post-container data-trp-post-id='133'>Pressure Switch</trp-post-container>

 

Pressure Switch Pictures

 

<trp-post-container data-trp-post-id='133'>Pressure Switch</trp-post-container> <trp-post-container data-trp-post-id='133'>Pressure Switch</trp-post-container>
<trp-post-container data-trp-post-id='133'>Pressure Switch</trp-post-container> <trp-post-container data-trp-post-id='133'>Pressure Switch</trp-post-container>

External Thread: G 1/4”

(Standard Version)

External Thread: 7/16-20”

(Optional Version)

 

Installation Picture

 

<trp-post-container data-trp-post-id='133'>Pressure Switch</trp-post-container> <trp-post-container data-trp-post-id='133'>Pressure Switch</trp-post-container>

 

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

Frequently Asked Questions (FAQ) About Pressure Switch

What is the main purpose of a pressure switch?

Down Down

Used to monitor and control pressure.

How to install pressure switching equipment?

Down Down

Secure and wire in place.

How to operate the pressure switch correctly?

Down Down

Adjust the pressure action according to the set value.

What are the causes of pressure switch failure?

Down Down

The diaphragm is damaged or the contacts are in poor contact.
ai (1).webp                  
       
                

Related Products

right
right
Soil Sensor

Soil Sensor

Soil Tester-LCD Screen

Soil Tester-LCD Screen

EC/TDS-TRA-600

EC/TDS-TRA-600

RO-8100

RO-8100

PH-TRA-600

PH-TRA-600

PH/ORP-6850

PH/ORP-6850

ORP-TRA-600

ORP-TRA-600

EC/TDS-500/600

EC/TDS-500/600

Related News

right
right
Turbidity Test Fixtures: Advanced and Reliable Quality Assurance Tools

May.22,2025

Turbidity Test Fixtures: Advanced and Reliable Quality Assurance Tools

Turbidity, as an important indicator for measuring liquid transparency, is widely used in environmental monitoring, food and beverage production, pharmaceutical industry, and other fields.

Total Dissolved Solids: Importance in Irrigation, Industrial Processes, and Applications

May.22,2025

Total Dissolved Solids: Importance in Irrigation, Industrial Processes, and Applications

Total Dissolved Solids refers to the total content of various inorganic salts and organic matter dissolved in water, and is one of the important indicators for measuring water quality.

Ro System Controller: Central nervous system in water purification systems

May.22,2025

Ro System Controller: Central nervous system in water purification systems

Reverse osmosis system, as an efficient water purification technology, has been widely used in industrial, commercial, and household fields.

Residual Chlorine Meter: A Key Guarantee for Ensuring Water Quality Safety

May.22,2025

Residual Chlorine Meter: A Key Guarantee for Ensuring Water Quality Safety

Residual chlorine, as an important indicator in the process of water disinfection, directly affects the safety and hygiene of drinking water and various industrial water.

PH oORP Controller: A Key Instrument for Water Quality Monitoring and Regulation

May.22,2025

PH oORP Controller: A Key Instrument for Water Quality Monitoring and Regulation

Water quality is an important indicator for measuring environmental health and industrial production.

Dissolved Oxygen Meter: A Key Tool for Accurately Measuring Dissolved Oxygen Levels in Aquatic Environments

May.22,2025

Dissolved Oxygen Meter: A Key Tool for Accurately Measuring Dissolved Oxygen Levels in Aquatic Environments

Dissolved oxygen is one of the important indicators for measuring water quality.

Understanding Turbidity Meter Types: Which One Is Right for Your Application?

Apr.21,2025

Understanding Turbidity Meter Types: Which One Is Right for Your Application?

Monitoring turbidity—an indicator of water clarity—is vital for applications ranging from drinking water treatment to environmental monitoring.

Understanding Total Dissolved Solids

Apr.21,2025

Understanding Total Dissolved Solids

Water may look clear, but that doesn’t mean it's pure. Hidden within every glass can be a range of minerals, salts, metals, and organic substances collectively known as total dissolved solids.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


id_IDIndonesian