Rotameter
Rotameter measures fluid flow based on the throttling principle. It changes the flow area of the fluid to keep the differential pressure above and below the rotor constant, so it is also called a variable flow area constant differential pressure flow meter, also known as a float flow meter.
Product Details
Contact Now
Product Details
Main Features
It has the characteristics of simple structure, intuitive, small pressure loss, and easy maintenance. The Rotameter is suitable for measuring small flows through pipes with a diameter of D<150mm, and can also measure the flow of corrosive media.
Main Specifications
Installation Method
RotaMeter has a simple structure and is generally installed vertically on a panel or a vertical pipe section. It is suitable for measuring the flow of low-velocity and low-flow media, but cannot measure media with more impurities. The fluid medium passes through the rotor flow meter from bottom to top.
1.Panel mounted Rotameter:
The LZM series Panel Rotameter is generally installed on the control panel, with both the inlet and outlet located at the back. Therefore, before installation, the inlet and outlet connection ports and the instrument fixing screw holes need to be in an open state.
![]() |
![]() |
1.1 Material:
Body |
Fitting |
Adjust Valve |
O-ring |
√ Acrylic
|
√ 1 .ABS 4. PA 2. PP 5. Brass(chrome plate) 3. PVC 6. SS |
√ 1.SS 1. Acrylic 2. PTFE |
√ 1.Silicon rubber 2.Fluororubber 3.EPDM |
Note:
Mark with √, the material of the Flow Meter is the General Configuration.
1.2 Technical Parameters:
Model |
Range |
Nm³/h(Gas) |
Screw Thread |
Accuracy |
Size(mm) |
||||||||
GPM(Liquid) (Gallon/Min) |
LPM(Liquid) (L/Min) |
A |
B |
C |
D |
E |
F |
G |
Hole size |
||||
LZM-15 |
0.05~0.5 0.1~1 0.2~2 0.3~3 0.5~5 |
0.2~2 0.5~4 1~7 1~11 2~18 10~100LPH 16~160LPH 25~250LPH |
0.1~1 0.2~2 0.5~3 0.6~6 1.2~12 1.6~16 2.5~25 1~10 |
(Male) 1/2"BSPT (Female) 1/4"BSPT |
±4% |
176 |
32 |
168 |
35 |
19 |
76 |
127 |
26 |
LZM-25 |
1~10 2~15 2~20 3~30 5~35 5~40 |
5~40 10~50 10~70 10~110 20~140 10~150 |
6~60m³/h 16~160m³m/h 25~250Nm³/h |
(Male) 1"BSPT |
234 |
45 |
226 |
46 |
27 |
100 |
160 |
38 |
|
LZM-50 |
5~45 10~50 10~60 20~80 25~100 30~150 |
10~170 50~190 20~220 90~300 100~350 100~500 |
|
(Male) 2"BSPT |
296 |
70 |
281 |
82.5 |
41 |
100 |
190 |
64 |
2.Pipeline Installation Rotameter:
The LZM-G Pipeline series Rotameter can be directly connected in a pipeline, with the inlet and outlet located at the upper and lower ends of the flow meter. The shape can be circular, square, or other polygonal forms (generally, the most commonly used is circular). The connection thread can be either external or internal, and the specifications and materials of the threads can be customized according to requirements.
![]() |
![]() |
|
Internal Thread Appearance Diagram |
External Thread Appearance Diagram |
2.1 Material:
Body |
Fitting |
Float |
O-ring |
√ 1. PC 2.PSU 3. AS |
√ 1 .ABS 4. Brass 2. PP 5. Brass(chrome plate) 3. PVC 6. SS |
√ 1.SS |
√ 1.Silicon rubber 2.Fluororubber 3.EPDM |
Note:
Mark with √, the material of the Flow Meter is the General Configuration.
2.2 Technical Parameters:
Model |
Range |
Nm³/h(Gas) |
Screw Thread |
Accuracy |
Size(mm) |
||||
GPM(Liquid) (Gallon/Min) |
LPM(Liquid) (L/Min) |
A |
B |
C |
D |
||||
LZM-15G |
0.05~0.5 0.1~1 0.15~1.5 0.2~2 0.25~2.5 0.3~3 0.5~5 |
0.18~1.8 0.4~4 0.5~5.5 1~7 1~9 1~11 1.8~18 |
0.8~8 1~10 1.2~12 1.6~16 2.5~25 6~60LPM |
(External) G1/2" 1/2"BSP (Internal) G1/2" 1/2"BSP |
±4% |
235 |
233 |
180 |
32 |
LZM-20G |
1~10 1.5~15 2~20 3~30 5~35 4~40 |
4~40 5~55 10~70 10~110 20~140 15~150 |
4~40 6~60 |
(External) G1/¼" 1//¼"BSP (Internal) G3/4" 3/4"BSP |
330 |
283 |
236 |
45 |
|
LZM-25G |
1~10 2~20 3~30 5~35 4~40 5~50 6~60 |
4~40 10~70 10~110 20~140 15~150 25~190 30~225 |
15~140 16~160 25~250 40~400 |
(External) G1/½" 1//½"BSP (Internal) G1" 1"BSP |
319 |
297 |
235 |
51 |
|
LZM-40G |
4~40 6~60 20~80 15~100
|
15~150 22~220 30~300 50~400 |
|
(Internal) G1/½" 1/½"BSP |
340 |
302 |
240 |
65 |
|
LZM-50G |
20~80 20~100 20~120 40~150 60~200 |
100~300 100~350 100~450 150~550 150~750 |
100~500 100~600 300~900 |
(External) G2" 2"BSP (Internal) G2" 2"BSP |
400 |
367 |
294 |
75 |
3. Rotameter Pictures:
![]() |
![]() |
![]() |
4.Rotameter Application:
Due to various excellent performance and reliability,the Rotameters are widely used in chemical, pharmaceutical, paper making, water treatment, RO water purify equipment etc.
![]() |
![]() |
Get in Touch
If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.
FAQS
What is the use of 2W series solenoid valve?
How to install 2W series solenoid valve?
How to use 2W solenoid valve correctly?
What is the cause of the 2W solenoid valve failure?
Related Products
Related News
May.22,2025
Turbidity Test Fixtures: Advanced and Reliable Quality Assurance Tools
Turbidity, as an important indicator for measuring liquid transparency, is widely used in environmental monitoring, food and beverage production, pharmaceutical industry, and other fields.
May.22,2025
Total Dissolved Solids: Importance in Irrigation, Industrial Processes, and Applications
Total Dissolved Solids refers to the total content of various inorganic salts and organic matter dissolved in water, and is one of the important indicators for measuring water quality.
May.22,2025
Ro System Controller: Central nervous system in water purification systems
Reverse osmosis system, as an efficient water purification technology, has been widely used in industrial, commercial, and household fields.
May.22,2025
Residual Chlorine Meter: A Key Guarantee for Ensuring Water Quality Safety
Residual chlorine, as an important indicator in the process of water disinfection, directly affects the safety and hygiene of drinking water and various industrial water.
May.22,2025
PH oORP Controller: A Key Instrument for Water Quality Monitoring and Regulation
Water quality is an important indicator for measuring environmental health and industrial production.
May.22,2025
Dissolved Oxygen Meter: A Key Tool for Accurately Measuring Dissolved Oxygen Levels in Aquatic Environments
Dissolved oxygen is one of the important indicators for measuring water quality.
Apr.21,2025
Understanding Turbidity Meter Types: Which One Is Right for Your Application?
Monitoring turbidity—an indicator of water clarity—is vital for applications ranging from drinking water treatment to environmental monitoring.
Apr.21,2025
Understanding Total Dissolved Solids
Water may look clear, but that doesn’t mean it's pure. Hidden within every glass can be a range of minerals, salts, metals, and organic substances collectively known as total dissolved solids.
If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.