M300f

● High resolution LCD display, 5.7 inches. ● Multi-reading feature allows auto-read, timed-read and continuous-read. ● Automatic/Manual temperature compensation ensures accurate results. ● Auto-hold feature senses and locks the measurement endpoint. ● Data Storage 500 sets (GLP-compliant). ● Support for USB or RS-232 communication. ● Reset feature automatically resumes all settings back to factory default options. ● IP54 waterproof.

Product Details

Product Details

Contact Now

Contact Now

Product Details

M300f

 

 

GENERAL FEATURES

  • • High resolution LCD display, 5.7 inches.
  • • Multi-reading feature allows auto-read, timed-read and continuous-read.
  • • Automatic/Manual temperature compensation ensures accurate results.
  • • Auto-hold feature senses and locks the measurement endpoint.
  • • Data Storage 500 sets (GLP-compliant).
  • • Support for USB or RS-232 communication.
  • • Reset feature automatically resumes all settings back to factory default options.
  • • IP54 waterproof.

Ion

  • •1-5 points calibration.
  • • Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, PX, etc.
  • • Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.
  • • Over 10 methods are built-in, including F- , Cl- , Br- , I- , NO3- , BF4- , NH4+ , K+ , Na+ , Ca2+ , Cu2+ , Pb2+, Ag+ and etc., user-defined method is supported.
 

pH

  • • 1-5 points calibration with Standard Recognition.
  • •Selectable pH buffer groups, including NIST, DIN, GB.
  • • Automatic electrode diagnosis with pH slope and offset display.

Conductivity

  • •1-3 points calibration with Standard Recognition.
  • • Settable parameters, including cell constant, temperature compensation coefficient and TDS factor.
  • • Temperature compensation type (none, linear, pure water).
 

 

Model

M300F-A

Parameters

pH/EC/ISE/Temp. (mV/ORP/pX/Resistivity/TDS/Sal.)

 

 

pH

Range

-2.00 to 20.00pH

Resolution

0.1, 0.01 pH

Accuracy

± 0.01 pH

Calibration Points

Up to 5

Standard Customization

Yes

Standard Recognition

NIST, GB and DIN buffers

Slope Limit

Yes

mV

Range

-2000.0 to 2000.0 mV

Resolution

0.1 mV

Accuracy

± 0.3 mV or ± 0.1%

 

pX

Range

-2.00 to 20.00

Resolution

0.1, 0.01 pX

Accuracy

± 0.01 pX

Calibration Points

Up to 5

 

ISE

Range

1E-9 to 9.999E9

Unit

mol/L, mmol/L, g/L, mg/L, μ g/L, ppm

Resolution

Up to 4 significant digits

Accuracy

± 0.5%

Calibration Points

Up to 5

 

 

Conductivity

Range

0.000 μ S/cm to 1000 mS/cm

Resolution

0.001 μ S/cm minimum,

various with range selection

Accuracy

± 1.0% FS

Reference Temperature

20, 25 ºC

Calibration Points

Up to 3

Standard Recognition

84 μ S/cm, 1413 μ S/cm, 12.88mS/cm

 

Resistivity

Range

5.00 Ω ·cm~20.00 M Ω ·cm

Resolution

0.01 Ω ·cm minimum

Accuracy

± 1.0% FS

TDS

Range

0.00mg/L~300g/L

Resolution

0.01mg/L minimum, various with range selection

Accuracy

± 1.0% FS

Salinity

Range

(0.00~8.00)%

Resolution

0.01%

Accuracy

± 0.2%

 

Temperature

Range

-5 to 110 ºC, 23 to 230 ºF

Unit

ºC, ºF

Resolution

0.1

Accuracy

± 0.2

Measurement

Reading Mode

Auto Read (Fast, Medium, Slow), Timed, Continuous

Reading Prompts

Reading, Stable, Locked

Temp. Compensation

ATC, MTC

Data management

Data Storage

500 results each

GLP Features

Yes

Inputs

pH Electrode

BNC(Q9)

DO with Temp. Probe

4-pin aviation connector

Conductivity with Temp. Probe

5-pin aviation connector

Outputs

USB

USB 2.0 flash memory device, PC

RS 232

printer

 

Display options

Backlight

Yes

Auto Shutdown

1~60 min, off

IP Rating

IP54

Date and Time

Yes

General

Power

AC Adapter, 100-240V AC input, DC9V output

Dimensions

242 × 195 × 68 mm

Weight

900g (1.98 lb)

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

Frequently Asked Questions (FAQ) About M300f A Multi Parameter Analyzer

What is the M300f analyzer used for?

Down Down

Used for multi-parameter detection and analysis work.

How do I operate the M300f analyzer?

Down Down

Start the detection after setting according to the process.

How do I maintain my M300f analyzer?

Down Down

Clean and calibrate components regularly.

What's wrong with the M300f analyzer?

Down Down

Sensor failure or circuit problem.
PH,-EC-full-set-2.webp                  
       
                

Related Products

right
right
WS-9200/9250

WS-9200/9250

JIRS-803C

JIRS-803C

JIRS-803C3

JIRS-803C3

JIRS-803C4

JIRS-803C4

JIRS-803C5

JIRS-803C5

Soil Sensor

Soil Sensor

Soil Tester-LCD Screen

Soil Tester-LCD Screen

EC/TDS-TRA-600

EC/TDS-TRA-600

Related News

right
right
The Importance of a Pressure Switch for RO System Safety

Aug.21,2025

The Importance of a Pressure Switch for RO System Safety

Reverse osmosis (RO) systems are critical for ensuring clean, safe water in various settings, and their reliability hinges on robust safety mechanisms.

Low Electrical Conductivity Materials for Insulation Purposes

Aug.21,2025

Low Electrical Conductivity Materials for Insulation Purposes

In industries ranging from electronics to power transmission, the demand for reliable insulation materials hinges on their electrical conductivity properties.

Key Considerations for Selecting Turbidity Testing Devices

Aug.21,2025

Key Considerations for Selecting Turbidity Testing Devices

In water quality management, accurate measurement of turbidity—cloudiness caused by suspended particles—is essential across industries.

How to Choose the Right ORP Controller for Industrial Applications

Aug.21,2025

How to Choose the Right ORP Controller for Industrial Applications

Selecting the right orp controller for industrial applications requires a deep understanding of specific operational needs, compatibility with existing systems, and reliability in diverse environments.

Best Practices for Calibrating an Optical Dissolved Oxygen Meter

Aug.21,2025

Best Practices for Calibrating an Optical Dissolved Oxygen Meter

Calibrating an optical dissolved oxygen meter is a critical step in ensuring accurate measurements of dissolved oxygen levels in water, a parameter vital for industries like aquaculture, environmental monitoring, and water treatment.

Benefits of Using an Automated Chlorine Monitor

Aug.21,2025

Benefits of Using an Automated Chlorine Monitor

In the realm of water quality management, maintaining precise chlorine levels is paramount for safety and compliance across industries.

Water Quality: Understanding TDS

Aug.19,2025

Water Quality: Understanding TDS

When it comes to water quality, the total suspended solids meter is an essential tool.

Turbidity Control: Clarity You Can Trust

Aug.19,2025

Turbidity Control: Clarity You Can Trust

In the quest for clear and safe water, the turbidity transmitter stands out as a crucial tool.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


fa_IRPersian