● High resolution LCD display, 5.7 inches. ● Multi-reading feature allows auto-read, timed-read and continuous-read. ● Automatic/Manual temperature compensation ensures accurate results. ● Auto-hold feature senses and locks the measurement endpoint. ● Data Storage 500 sets (GLP-compliant). ● Support for USB or RS-232 communication. ● Reset feature automatically resumes all settings back to factory default options. ● IP54 waterproof.

Product Details

Product Details

Contact Now

Contact Now

Product Details

 

 

GENERAL FEATURES

  • • High resolution LCD display, 5.7 inches.
  • • Multi-reading feature allows auto-read, timed-read and continuous-read.
  • • Automatic/Manual temperature compensation ensures accurate results.
  • • Auto-hold feature senses and locks the measurement endpoint.
  • • Data Storage 500 sets (GLP-compliant).
  • • Support for USB or RS-232 communication.
  • • Reset feature automatically resumes all settings back to factory default options.
  • • IP54 waterproof.

Ion

  • •1-5 points calibration.
  • • Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, PX, etc.
  • • Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.
  • • Over 10 methods are built-in, including F- , Cl- , Br- , I- , NO3- , BF4- , NH4+ , K+ , Na+ , Ca2+ , Cu2+ , Pb2+, Ag+ and etc., user-defined method is supported.
 

pH

  • • 1-5 points calibration with Standard Recognition.
  • •Selectable pH buffer groups, including NIST, DIN, GB.
  • • Automatic electrode diagnosis with pH slope and offset display.

Conductivity

  • •1-3 points calibration with Standard Recognition.
  • • Settable parameters, including cell constant, temperature compensation coefficient and TDS factor.
  • • Temperature compensation type (none, linear, pure water).
 

 

Model

M300F-A

Parameters

pH/EC/ISE/Temp. (mV/ORP/pX/Resistivity/TDS/Sal.)

 

 

pH

Range

-2.00 to 20.00pH

Resolution

0.1, 0.01 pH

Accuracy

± 0.01 pH

Calibration Points

Up to 5

Standard Customization

Yes

Standard Recognition

NIST, GB and DIN buffers

Slope Limit

Yes

mV

Range

-2000.0 to 2000.0 mV

Resolution

0.1 mV

Accuracy

± 0.3 mV or ± 0.1%

 

pX

Range

-2.00 to 20.00

Resolution

0.1, 0.01 pX

Accuracy

± 0.01 pX

Calibration Points

Up to 5

 

ISE

Range

1E-9 to 9.999E9

Unit

mol/L, mmol/L, g/L, mg/L, μ g/L, ppm

Resolution

Up to 4 significant digits

Accuracy

± 0.5%

Calibration Points

Up to 5

 

 

Conductivity

Range

0.000 μ S/cm to 1000 mS/cm

Resolution

0.001 μ S/cm minimum,

various with range selection

Accuracy

± 1.0% FS

Reference Temperature

20, 25 ºC

Calibration Points

Up to 3

Standard Recognition

84 μ S/cm, 1413 μ S/cm, 12.88mS/cm

 

Resistivity

Range

5.00 Ω ·cm~20.00 M Ω ·cm

Resolution

0.01 Ω ·cm minimum

Accuracy

± 1.0% FS

TDS

Range

0.00mg/L~300g/L

Resolution

0.01mg/L minimum, various with range selection

Accuracy

± 1.0% FS

Salinity

Range

(0.00~8.00)%

Resolution

0.01%

Accuracy

± 0.2%

 

Temperature

Range

-5 to 110 ºC, 23 to 230 ºF

Unit

ºC, ºF

Resolution

0.1

Accuracy

± 0.2

Measurement

Reading Mode

Auto Read (Fast, Medium, Slow), Timed, Continuous

Reading Prompts

Reading, Stable, Locked

Temp. Compensation

ATC, MTC

Data management

Data Storage

500 results each

GLP Features

Yes

Inputs

pH Electrode

BNC(Q9)

DO with Temp. Probe

4-pin aviation connector

Conductivity with Temp. Probe

5-pin aviation connector

Outputs

USB

USB 2.0 flash memory device, PC

RS 232

printer

 

Display options

Backlight

Yes

Auto Shutdown

1~60 min, off

IP Rating

IP54

Date and Time

Yes

General

Power

AC Adapter, 100-240V AC input, DC9V output

Dimensions

242 × 195 × 68 mm

Weight

900g (1.98 lb)

Get in Touch

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.

* Name

* E-mail

Phone

*Message

FAQS

Frequently Asked Questions (FAQ) About M300f A Multi Parameter Analyzer

What is the M300f analyzer used for?

Down Down

Used for multi-parameter detection and analysis work.

How do I operate the M300f analyzer?

Down Down

Start the detection after setting according to the process.

How do I maintain my M300f analyzer?

Down Down

Clean and calibrate components regularly.

What's wrong with the M300f analyzer?

Down Down

Sensor failure or circuit problem.
PH,-EC-full-set-2.webp                  
       
                

Related Products

right
right
Soil Tester

Soil Tester

EC/TDS-TRA-600

EC/TDS-TRA-600

RO-8100

RO-8100

PH-TRA-600

PH-TRA-600

PH/ORP-6850

PH/ORP-6850

ORP-TRA-600

ORP-TRA-600

EC/TDS-500/600

EC/TDS-500/600

EC/TDS/RM-6850

EC/TDS/RM-6850

Related News

right
right
Understanding Turbidity Meter Types: Which One Is Right for Your Application?

Apr.21,2025

Understanding Turbidity Meter Types: Which One Is Right for Your Application?

Monitoring turbidity—an indicator of water clarity—is vital for applications ranging from drinking water treatment to environmental monitoring.

Understanding Total Dissolved Solids

Apr.21,2025

Understanding Total Dissolved Solids

Water may look clear, but that doesn’t mean it's pure. Hidden within every glass can be a range of minerals, salts, metals, and organic substances collectively known as total dissolved solids.

Transmitter 4 20mA Technology

Apr.21,2025

Transmitter 4 20mA Technology

In the world of industrial automation and process control, accurate signal transmission is everything.

Smart RO System Controller

Apr.21,2025

Smart RO System Controller

In today’s world, clean water isn’t just a luxury—it’s a necessity. Whether in residential settings or industrial applications, ensuring a consistent supply of high-quality water has become vital.

Residual Chlorine Meter is Essential

Apr.21,2025

Residual Chlorine Meter is Essential

Chlorination is one of the most widely used methods for disinfecting water, whether it’s for municipal supply, swimming pools, or industrial processes.

Essential Water Sampler Types

Apr.21,2025

Essential Water Sampler Types

When it comes to environmental analysis, wastewater treatment, or drinking water inspection, water sampler types play a crucial role in collecting representative water samples for laboratory analysis.

Dissolved Oxygen Meter

Apr.21,2025

Dissolved Oxygen Meter

Water may look clean, but what’s happening on the molecular level often tells a different story.

Different Types of Sensors in Industrial Automation

Apr.21,2025

Different Types of Sensors in Industrial Automation

In the rapidly evolving age of smart manufacturing and Industry 4.0, the different types of sensors deployed across production facilities are nothing short of transformative.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.